INVERTER CONFIGURATION STATUS 3 and INVERTER CONFIGURATION COMMAND 3 and additional SPNs Proposed

Doru Botez of Xantrex has proposed additional value descriptions for INVERTER CONFIGURATION STATUS 3 and INVERTER CONFIGURATION COMMAND 3

4 – Line 1 Master (for series stacking)
5 – Line 2 Slave (for series stacking)
6 – Line 1 Slave (for series stacking)
7 - Phase 1 Master (3-for-phase stacking)
8 – Phase 2 Master (3-for-phase stacking)
9 - Phase 3 Master (3-for-phase stacking)
10 – Phase 1 Slave (3-for-phase stacking)
11 – Phase 2 Slave (3-for-phase stacking)
12- Phase 3 Slave (3-for-phase stacking)

Justification: Expanding the definition of “Stack Mode” and adding four new SPNs identified below

MSB ISB LSB Description
2 Instance 2 Control/Power Board Temperature
2 Instance 3 Cooling Fan

0x83 Instance 0 Anti-Islanding Frequency
0x83 Instance 1 Anti-Islanding Voltage